Spec: | 60V 5A | IP Protection Class: | IP20 |
---|---|---|---|
Input Power: | AC 380V ±10% / 60Hz | Input Active Power: | 6278W |
Noise: | <85dB | Resolution Ratio: | AD:16bit;DA:16bit |
Highlight: | 60V 5A EV Battery Testing Equipment,IP20 EV Battery Testing Equipment,60V 5A Battery Charge Tester |
60V 5A EV Battery Testing Equipment
60V5A Charge And Discharge System
BTS-60V5A Standard Power Battery Testing System , Battery Continuous charge ,Battery Forced Discharge
Technical Parameter:
BTS-60V5A Battery tester |
|||||||||||||
Model Number: |
BTS- |
60 |
V |
5 |
A |
Battery tester |
Material code: |
CT-4016 |
-60V5A |
- |
NTA |
- |
P |
items |
Parameter |
||||||||||||
Input power |
AC 380V ±10% / 60Hz |
||||||||||||
Input active power |
6278 |
W |
|||||||||||
resolution ratio |
AD:16bit;DA:16bit |
||||||||||||
Input impedance |
≥100kΩ |
||||||||||||
voltage |
Constant voltage range |
0.3V~60V |
|||||||||||
Minimum discharge voltage |
3V |
||||||||||||
accuracy |
± 0.1% of FS |
||||||||||||
stability |
± 0.1% of FS |
||||||||||||
current |
Output range/channel |
0.025A~5A |
|||||||||||
accuracy |
± 0.1% of FS |
||||||||||||
Constant voltage cut-off current |
0.01A |
||||||||||||
stability |
± 0.1% of FS |
||||||||||||
Power |
Output range/channel |
300W |
|||||||||||
stability |
±0.2% of FS |
||||||||||||
time |
Current response time |
maximum current rising time20ms |
|||||||||||
working step time range |
≤(365*24)h/working step |
||||||||||||
Data record |
Record data conditions |
Minimum time interval:100ms |
|||||||||||
Minimum voltage interval:120mV |
|||||||||||||
Minimum current interval:10mA |
|||||||||||||
Record frequency |
10Hz |
||||||||||||
Charge |
Charge mode |
constant-current charge,constant-voltage charge,constant voltage and current charge |
|||||||||||
cut-off conditions |
Voltage,current,relative time,capacity,-△V |
||||||||||||
discharge |
Discharge mode |
constant current discharge, constant watt discharge |
|||||||||||
cut-off conditions |
Voltage,current,relative time,capacity,-△V |
||||||||||||
Impulse mode |
Charge |
Constant current,Constant power |
|||||||||||
Discharge |
Constant current,Constant power |
||||||||||||
Minimum impulse width |
500ms |
||||||||||||
Number of pulses |
one single pulse working step can support 32 different pulses |
||||||||||||
Continuous switch of charge and discharge |
one pulse working step can continuously switch from charge to discharge |
||||||||||||
cut-off conditions |
Voltage,relative time |
||||||||||||
DCIR test |
Support customized picking up point to perform DCIR calculation |
||||||||||||
|
|
||||||||||||
cycle |
Loop test range |
1~65535 times |
|||||||||||
Single cycle working steps |
254 |
||||||||||||
Loop nest |
Nested loop function,max 3 layers |
||||||||||||
Protection |
● Data Protection |
||||||||||||
● off-line test |
|||||||||||||
● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time |
|||||||||||||
●anti reverse connection |
|||||||||||||
IP Protection Class |
IP20 |
||||||||||||
Channel feature |
constant current and voltage source ;double closed-loop; |
||||||||||||
Channel control mode |
independent |
||||||||||||
Current/voltage detection sampling |
four-wire connection |
||||||||||||
noise |
<85dB |
||||||||||||
data base |
MySQL centralized management of test datas |
||||||||||||
upper computer communication mode |
TCP/IP |
||||||||||||
Server disk Configuration |
500GB |
||||||||||||
Data output mode |
EXCEL 2003,2010,TXT |
||||||||||||
Server operating system |
Windows 7 |
||||||||||||
communication interface |
ethernet |
||||||||||||
Working environment requirement |
|||||||||||||
item |
parameter |
||||||||||||
working temp. range |
0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
||||||||||||
Storage temp. range |
-10℃~50℃ |
||||||||||||
Working environment relative humidity range |
≤70% RH(no water vapor condensation) |
||||||||||||
Storage environment relative humidity range |
≤80% RH(no water vapor condensation) |
||||||||||||
Clamp specification and size |
|||||||||||||
item |
parameter |
||||||||||||
Clamp type |
Polymer clamp |
||||||||||||
Pic |
|
|
|
||||||||||
Alligator clamp |
Polymer clamp |
cable feet clamp |
|||||||||||
Pictures are for reference only,real objects shall prevail.Choose one |
|||||||||||||
Cabinet size/unit(W*D*H)(mm) |
30U(24”),730*600*1520 |
||||||||||||
Equipment pic |
|
||||||||||||
Pictures are for reference only,real objects shall prevail. |
|||||||||||||
Auxiliary channel |
type |
Temperature,voltage |
|||||||||||
Temp. range |
-25℃~110℃ |
||||||||||||
Temp. range |
±1℃ |
||||||||||||
Temp. resolution ratio |
0.1℃ |
||||||||||||
Voltage range |
-5V~5V |
||||||||||||
Voltage accuracy |
± 0.1% of FS |
||||||||||||
Available auxiliary temp.channel/channel |
customized(248 channel at most) |
||||||||||||
Available auxiliary voltage channel/channel |
customized(248 channel at most) |
||||||||||||
Protaction condition of Auxiliary channel |
● security conditions of Auxiliary channel can be set including temperature upper/lower limit,voltage upper/lower limit and delay time,voltage difference of single cell |
||||||||||||
Note:incompatible with battery that has protection plate with soft start function. |