| Test Sample: | Blanket's Flexible Fabric | Application: | Aging Test | 
|---|---|---|---|
| Volume: | 150L | Temp. Range: | -40 ℃~ +150 ℃ | 
| Humidity Range: | 20 %RH~ 98 %RH | Type: | Chamber | 
| Highlight: | Programmable IEC Test Equipment,150L IEC Test Equipment,IEC 60335 Programmable Temperature Humidity Chamber | ||
Programmable IEC Test Equipment
IEC60335-2-17 Programmable Temperature Humidity Chamber
IEC 60335 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃, 20 %RH~ 98 %RH
Standard
IEC60335-2-17, Clause 21.110.3, Clause 21.111.2.
Application
It is used to process the aging test for the blanket’s flexible fabric parts.
Test sample
Blanket’s flexible fabric parts.
Feature
Box type
Parameters
| Product Name | Programmable Temperature Humidity Chamber | 
| Volume, size and weight | |
| Working Volume | 150L (can be customized) | 
| Inner size | W500mm × H600mm × D500mm | 
| Outer size | W1020mm × H1000mm × D1460mm | 
| Weight | 300KG | 
| Performance | |
| Test environmental conditions | Environmental temperature +5~+28℃, relative humidity≤85%, under the condition that no sample inside the test chamber | 
| Test method | According to IEC60068-2, IEC60598-1 | 
| Temperature range | -40℃~+150℃ | 
| Temperature control precision | ±0.2℃ | 
| Humidity control precision | ±2.5% RH | 
| Temperature uniformity | ±2℃ | 
| Humidity uniformity | ±3.0% RH | 
| Heating up time | 3℃/min (Average heating up rate) | 
| Cooling down time | 1℃/min (Average cooling down rate) | 
*Note: Please refer to below humidity use range chart!

4. Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH.
* To guarantee above 2~4 performance, should be measured 30 minutes after the temperature sensing measurements is stable!
5. Temperature and humidity distribution uniformity: ±2℃; ±3%RH.
*Note: To guarantee below 6~11 performance, the measuring positions should be each wall’s 1/6 positions of the test zone, and should be measured 30 minutes after the temperature is stable!
6. Heating time: Heating from the room temperature to 150℃, the total heating time is 50 mins (under non-load state).
7. Cooling time: Cooling from the room temperature to -40℃, the total cooling time is 40mins (under non-load state).
8. Inner chamber dimensions: test area: 50×60×50cm(W×H×D).
*Note: The volume of placing samples should not exceed 2/3 of the capacity of the test zone.
9. Equipment installation space: at least 920×1600×870cm(W×H×D).
10. Test chamber door: 80 × 105 cm(W×H), total 1.
11. Power source: AC 1 ∮ 220 V 50 Hz MAX 40 A
Picture for reference