Outer: | 3700X1600X2100mm | Dust: | Diameter <150μm |
---|---|---|---|
Dust Concentration: | 10.6G / M³ ± 7G | Airflow Speed: | 8.9m / S ± 1.5 |
Dust Composition: | CaCO 3 , MgCO 3 , MgO, TiO 2 | Ferric Oxide (Fe 2 O 3 ): | 10±5% |
High Light: | 15KW Environmental Test Chambers,150μm DustEnvironmental Test Chambers,15KW Blowing Sand Test Chamber |
15KW Environmental Test Chambers PLC Touch Screen Control System
Blowing Dust Test Chamber
Purpose
Dust (< 150 µm) procedure. This test is performed to help evaluate the ability of materiel to resist the effects of dust that may obstruct openings, penetrate into cracks, crevices, bearings, and joints, and to evaluate the effectiveness of filters
Standard
MIL-STD-810G.
Design principles
Its structure is a funnel,a collecting hole for dust on the bottom,on the right side of this hole is equipped with a suction inlet of turbine circulating fan.Send the pumped dust into the bottom of inner chamber and then to the left side and go upwards;blow the dust into test chamber from the left side; the dust should be blown rightwards in a horizontal direction and then begin circulation
Material
1. Material: SUS304 stainless steel plate
3. Chamber door with a large observation window
4. Unique duct design, to ensure the concentration of laminar flow laminar flow
5. Basic structure: Pre-treatment box, test chamber, vacuum port, dust box, circulating dust device, vacuum system, dust tank, flow valve, heating system, backflow vane, sample carousel, screen, concentration meter And so on.
Technical Parameters
1, Model: KP-DCJB1000
2, studio size (mm): 1000X1000X1000mm (W × D × H)
3, Dimensions (mm): 3700X1600X2100mm (W × D × H)
7, dust: diameter <150μm;
8, inside the chamber, the dust concentration in the pipeline is 10.6G / m³ ± 7G
9, airflow speed: 8.9m / s ± 1.5 (adjustable)
10,Dust Composition:CaCO 3 , MgCO 3 , MgO, TiO 2 : 5%
Ferric oxide (Fe 2 O 3 ) : 10±5%
Aluminum oxide (Al 2 O 3 ):20±10%
Silicon dioxide (SiO 2 ):remaining percentage (50 to 80 %)
11, temperature: 23-80C °
12, the rate of temperature change: ≥ 3C °
13, function: blowing dust, blowing sand, dust falling (high temperature operation)
14, environmental requirements: 22 ℃ ± 3.
15, power supply: 380V 3Phase, power: 15KW 50HZ
Control System
1. PLC and touch screen intelligent control system
2. PT100 test sensor
3. Sand and dust concentration meter
4. Anemometer (hand-held) to adjust the wind speed before testing.
5. Instrument over-temperature protection
6. Power phase loss protection
7. Leakage circuit breaker
8. Power: AC380V 50Hz
9. Door: tempered glass door
10. Vacuum pump 60-600L / H
11. Regulating valve, nozzle, pressure regulator
12. Controller: Adopt programmable controller (this controller has many kinds of arbitrarily setting control functions as below)
a. blowing dust time (stop, blow) h/m/s adjustableb. Cycle time: adjustable
c. Default test time: 0s ~ 999h99m99s adjustable
d. Power on: off - on - off