products

GB 18580 GB 18584 Medical Testing Equipment VOC Emission Test Chamber

Basic Information
Place of Origin: China
Brand Name: KINGPO
Certification: calibration certificate
Model Number: 3 models available
Minimum Order Quantity: 1
Detail Information
Standard: GB 18580 Environmental Temperature: 5~35℃
Humidity: ≤90%R.H Adjustable Range Of Temperature: 20~100℃
Adjustable Range Of Humidity: 40~70%R.H(20℃~30℃) Pressure: 10±5pa
High Light:

GB 18584 Medical Testing Equipment

,

GB 18580 VOC Emission Test Chamber

,

GB 18584 VOC Emission Test Chamber


Product Description

GB 18580 GB 18584 Medical Testing Equipment VOC Emission Test Chamber

 

VOC Release Capsule Of Interiors

 

Product Purpose

VOC release capsule of interiors can provide standard testing environment(such as appointed temperature,relative humidity,air exchange rate and airflow rate) or simulate real indoor environment and test the pollutant release rate and release properties of various indoor materials and products,then it can:

• Confirm the influence of environment variables on the release rate and release properties of materials and products;

• Grade materials and products according to their release properties;

• Develop and validate the proposed model of indoor air pollutions;

• Evaluate indoor air quality(IAQ) according to the data and proposed model of indoor pollutants;

 

Implementation Standards

• GB 18580 ''Indoor Decorating and Renovating Materials Limit of Formaldehyde Emission of Manmade Board and its Products''

• GB 18584 ''Indoor Decorating and Renovating Materials Limits of Harmful Substances from Wooden Furniture(Exposure draft)

• GB 18587 ''Indoor Decorating and Renovating Materials Releasing Limitation of Harmful Substances from Carpet,Carpet Pad and Carpet Adhesive''

• ASTM6007--02 "Standard test methods for measurement of Formaldehyde concentration in Gases released from wood products with small scale environmental chamber"

• ENV717-1 "Environmental chamber method for measurement of formaldehyde emission of manmade board.

• EN13419-1 "Determination of VOCs Release quantity of building products Chapter One the method for releasing and testing the environmental chamber"

• HJ571-2010 "Technical requirements for environmental labeling manmade board and its products"

• HJ566-2010 "Technical requirements for environmental labeling manmade board and its products"

• ISO12219-4

• VDA-276

 

Reference Standard

• ASTM D5116-97 "Standard guide for determination of organic release from interior materials and products with small scale environmental chamber

• ASTM D6330-98 "Standard operation for determination of VOCs(excluding formaldehyde) release from wooden board with small environmental chamber under specified test conditions"

• ASTM D6670-01 "Standard operation for determination of organic release from interior materials and products with full scale environmental chamber"

• ASTM D6670-01 "Standard test methods for determination of formaldehyde concentration and release rate in gases released from wood products with large scale environmental chamber"

 

Technical Parameters:

Product Model

V-1000A

V-1000B

V-2000

Volume of climatechamber(WxDxH)mm

1580*800*800

900*1000*1100

910*2000*1100

Door of testing room (WxH)mm

800*800

1770*2900*2370

1770*2900*2370

Environmental temperature

5~35℃

Environmental humidity

≤90%R.H

Requirements for Environmental

Cleanliness No pollutant source in the surrounding environment TVOC 500μg/m³

Adjustable range of temperature

20~100℃ high temperature cleaning mote than 250℃

Adjustable range of humidity

40~70%R.H(20℃~30℃)

Pressure

10±5pa

Temperature fluctuation

±0.3℃(fluctuation)

Temperature deviation

±0.5℃(deviation)

Humidity fluctuation

±2.5%R.H

Humidity deviation

±30%

Air exchange rate

0.2~5/h±5%(optional with specifications of greater exchange rate )

Power

Alternating current 380V/50Hz three-phase power supply 4/5 wiring system

Starting power

25kw

30kw

36kw

44kw

50kw

55kw

65kw

93kw

Operating power

12kw

13kw

14.8kw

17.9kw

20kw

22kw

26kw

38kw

Rate of recovery

Formaldehyde,octanol,4 phenyl Cyclohexene,dodecane and tetradecane have a recovery rate larger than 80%

Clean air system

Standard configuration

Background concentration for formaldehyde

single VOC has a concentration smaller than 15μg/m³,dust filtrated TVOC smaller than 20μg/m³

 

Hot Tags: voc release capsule of interiors, China, manufacturers, suppliers, factory, custom, wholesale, IEC60695-11-5 Needle Flame Test Chamber, Hot Windind Temperature Tester Double Channel, Ingestion Gauge For Small Cell Safety Test, BS1363 Plug Socket Measuring Gauge, Blocked Microorganism Penetration Test, Flexible Cables Flexing Tester

Contact Details
Sales Manager

WhatsApp : +8613751216827